Wells and Pumps
No water from the well
by Edward J. Thunderbird
Faucets dry? Check these in order before calling the well company.
DifficultyModerate
Time30 minutes to diagnose
Do it yourself$0 to $50
Hire a pro$150 to $400 for a service call; $1,500 to $3,000+ to replace a submersible pump
Signs of the problem
- No water at any faucet
- Pump runs but no water
- Pump will not run
- Breaker keeps tripping
How it works
A well system has a pump (in the well or in a pump house), a pressure switch that turns it on and off, and a pressure tank that stores water under pressure. No water usually means no power to the pump, a bad pressure switch, a failed pump or capacitor, or, in winter, a frozen line.
Tools and parts
Tools
- Screwdrivers (Tools Critical)
- Pliers (Tools Critical)
- Non-contact voltage tester
- Multimeter
- Tire pressure gauge
Parts and what they cost
| Part | Typical cost |
|---|---|
| Pressure switch | $25 to $45 |
| Control box capacitor (3-wire pumps) | $15 to $40 |
| Heat tape (for freezing) | $30 to $60 |
Total cost
| Cost | |
|---|---|
| Do it yourself | $0 to $50 |
| Hire a pro | $150 to $400 for a service call; $1,500 to $3,000+ to replace a submersible pump |
Costs are typical U.S. prices checked November 18, 2026; they vary by region and change often. Pro prices include labor. Fix Critical is not paid by any store or brand.
Step by step
Safety first
- Well pumps run on 240 volts. Turn off the breaker and test with a non-contact tester before touching anything.
- Never tap the switch contacts with a tool while live.
- Pulling a submersible pump is a two-person job with special gear.
- Check the breaker for the well pump. If it is tripped, reset it once. If it trips again, stop and call a pro.
- Look at the pressure gauge near the tank. If it reads near zero and the pump is not running, the pressure switch may be stuck.
- With the breaker OFF, remove the pressure switch cover. Look for burned or pitted contacts and ants or bugs. The small tube under the switch can plug with sediment; clean it.
- In freezing weather, check the pump house and pipes for ice. Thaw with a hair dryer or heat lamp, never a flame.
- If the switch has power and the contacts close but the pump does not run, the pump, capacitor or wiring has failed: call a well service.
Maintenance: keep it from happening again
- Check tank pressure once a year.
- Keep the pump house insulated and heated in winter.
- Test water quality every year (bacteria and nitrates).
When to call a pro
Breaker trips repeatedly, the pump runs with no water (well may be low or pipe broken), or the pump needs pulling.